Whether you lost the physical booklet that came in the box or you are trying to program a newly installed unit, this comprehensive user manual covers everything you need to know. 1. Product Overview and Specifications
| Terminal | Label | Connection | Wire Gauge (AWG) | | :--- | :--- | :--- | :--- | | 1 | +12V | Power Supply Positive (10-14V DC) | 18-22 | | 2 | GND | Power Ground / Common Negative | 18-22 | | 3 | NO | Normally Open (Magnetic Lock) | 18 | | 4 | COM | Common (Lock Relay) | 18 | | 5 | NC | Normally Closed (Electric Strike - Fail Secure) | 18 | | 6 | PUSH | Exit Button Signal (Short to GND to activate) | 22 | | 7 | SEN | Door Contact Sensor (Magnetic Reed Switch) | 22 | | 8 | AL+ | Alarm Output (+) | 22 | | 9 | AL- | Alarm Output (-) | 22 | | 10 | +12V | Reader Power (For external reader – rarely used) | 22 | | 11 | DATA0 | Wiegand Data 0 (For external reader) | 22 | | 12 | DATA1 | Wiegand Data 1 (For external reader) | 22 |
Before powering on the device, you must double-check that the input voltage is exactly DC 12V and that the positive and negative polarity is correct. Reversing the polarity may cause irreversible damage to the system.
Connect the wire of the V2000-C and the Negative (-) terminal of the lock to the Power Supply GND.